click here for project pricing & enquiries
ins_g

NEW ERA CRADLE INSTALLATION GUIDELINES

New Era Cradles are simple and quick to install and can be used immediately after the top floor covering is fitted because there is no drying time needed after installation.


Please take a look below at the diagram which illustrates the neccessary requirements of setting our battens in staggered lengths which enchances the strength of the system.

Please check the acoustic requirements before installation.

inst_sch
FLOOR-
BOARD
LENGTH
Random
Length
Ply/Clipboard
2400mm
Junckers
3700mm
Boen
2200mm
Batten
Centres

305mm    305mm

400mm    400mm

411mm    411mm

367mm    367mm

Batten
Thickness

36mm    48mm

36mm    48mm

36mm    48mm

36mm    48mm

Cradle
Centres

450mm    600mm

450mm    600mm

450mm    600mm

450mm    600mm

Cradles
req’d / m2

8.75no    6.5no

6.6no    4.9no

6.6no    5no

7no    5no

LM Batten
req’d / m2

3.6Lm    3.6Lm

2.7Lm    2.7Lm

2.7Lm    2.7Lm

2.88Lm    2.88Lm